Skip to main content

Table 11 Results of the STD ALBAYZIN 2014 evaluation on test data

From: Spoken term detection ALBAYZIN 2014 evaluation: overview, systems, results, and discussion

System ID MTWV ATWV p(FA) p(Miss) Precision Recall F-measure
Fusion 0.4872 0.4868 0.00003 0.483 0.9666 0.6207 0.7560
WL-Kaldi 0.5451 0.5350 0.00008 0.374 0.9104 0.7473 0.8209
W1B-HTK 0.2026 0.1980 0.00016 0.642 0.7981 0.4927 0.6093
WL-ATWV-Kaldi 0.2018 0.1972 0.00007 0.731 0.8829 0.3194 0.4691
WL-WER-Kaldi 0.1389 0.1316 0.00003 0.828 0.8498 0.2561 0.3936
P1B-HTK 0.0391 0.0297 0.00004 0.917 0.7275 0.1222 0.2093