Skip to main content

Table 13 Results (mean F measure) of onset detection for hearing dummies (HD) compared to the normal hearing (NH) model

From: A computational study of auditory models in music recognition tasks for normal-hearing and hearing-impaired listeners

Task

Monophonic

Melody onsets

All onsets

Hearing impairment

NH

HD1

HD2

HD3

NH

HD1

HD2

HD3

NH

HD1

HD2

HD3

Cello

0.79

0.67

0.74

0.78

0.46

0.37

0.44

0.45

0.53

0.46

0.50

0.53

Clarinet

0.76

0.75

0.77

0.72

0.72

0.58

0.70

0.69

0.71

0.62

0.70

0.69

Trumpet

0.98

0.99

0.98

0.98

0.87

0.70

0.80

0.86

0.85

0.74

0.81

0.83

Mean

0.84

0.80

0.83

0.83

0.68

0.55

0.65

0.67

0.69

0.61

0.67

0.68