Table 14 Mean error rates of pitch detection methods for hearing dummies (HD) compared to the normal hearing (NH) model (italics indicates the best result for each dummy)

From: A computational study of auditory models in music recognition tasks for normal-hearing and hearing-impaired listeners

Method

NH

HD1

HD2

HD3

SACF max.

0.54

0.67

0.60

0.56

SACF thresh.

0.18

0.44

0.34

0.22

DFT + RF

0.08

0.32

0.29

0.10

DFT + SVM

0.07

0.32

0.24

0.09

ACF + RF

0.20

0.91

0.42

0.21

ACF + SVM

0.17

0.90

0.40

0.18